DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-20Initialization and Recovery
1
Initialization and Recovery
When the system is initially powered up, or wh en an existing system experienc es
a catastrophic fault that interrup ts its basic functions, the syste m either initializes
or reboots.

Initialization

Upon initialization, no forms (not even Customer Options) are available until the
Offer Category is set. (The remote INADS channel is available.) To set the
customer options (INADS password only), do the following:
1. Enter change system-parameters offer-options (init and inads log ins
only) and the following form d isplays:
Field descriptions
2. After these two fields are filled and you press Ente r, the system displays:
WARNING: Activating Offer Category may set unchangeable
limits.
This is to let you know that the Offer Category along with the m odel
determine the system cap acities (limits) and allowab le hardware.
3. Select the Submi t option to submit the form.
4. Use the save translations command to make the chang es permanent.
!CAUTION:

To avoid potential loss of service, ensure that your system’s

translations are protected b y saving them to the PCM/CIA card.

Offer category Type either A or B.
Activate offer? Type y if the entry for Offer category is correct and press Ta b .
Type n if there is an error in the Offer category field an d press
Tab . Re-enter the correct Offer Categ ory.
change system-parameters offer-options
OFFER OPTIONS FORM
Offer Category: _
Activate Offer? _
WARNING: Need to save translations and reboot to make the change permanent.