DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1052TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. The far-end has reported that this c hannel is not administered. The trunks
are placed in the out-of-servic e state.
b. The Signaling link is down. See the following Au x Data explanation:
Aux data 8 in dicates the Signaling Link is down.
Aux data 9 ind icates the Port is out of service.
c. The Service State Audit failed. The test will be run eve ry 15 minutes until it
passes.
d. Unexpected Restart message; this error causes no action and is logged
only.
e. B-Channel Rejection Event; this action causes the Service State Audit, the
Call State Audit, and the Test Call Audit to be executed .
Table 3-467. TBRI-TRK Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test Port UCSSPP sh r 1
513 (a) Service State Audit
(Test #256) WARN ING OFF
1793 (b) 8, 9 WARNING OFF
3073 (c) Service State Audit
(Test #256)
3585 (d)
3841 (e) WARNING OFF
Continued on next page