DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-626DTMR-PT [Dual Tone Multifrequency Port (TTR)]

3
Tone Detector Audit/Update Test (#43)
The DTMR port is refreshed with all time slot information and sanity aud it is performed on the DTMR port.
1003 ABORT The system could not allocate a Tone Generator for the test connection.
This could happen when the system is heavily loaded or there is not a
Tone-Clock circuit pack in the port network when this test is being
executed.
1. Make sure there is a Tone-Clock circuit pack in the same port network.
2. If a Tone-Clock circuit pack is missing, install one in the same port
network.
3. Allow about 1 minute for the Tone-Clock maintenance to run on the
newly inserted Tone-Clock circuit pack.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2006 ABORT DTMF detection failed . This could be c aused by the adm inistered
companding mode of the system not matching that of the Tone Detector
circuit pack.
1. Make sure that companding mode of the system matches that of the
Tone Detector.
1-3 FAIL DTMF digits were not correctly detected .
1. Run the Short Test Sequence: test port PCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but
system capacity will be reduced. In ord er to restore the system
performance to nor mal, replace the Tone Detector c ircuit pack
containing the defective DTMR port.
PASS The DTMR port is able to detect all the touch-tone digits.
Table 3-257. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page