DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-625DTMR-PT [Dual Tone Multifrequency Port (TTR)]

3
System Technician-Demanded Tests: Descriptions
and Error Codes

Always investigate tests in the order p resented in the table below whe n

inspecting errors in the sy stem. By clearing error cod es associated with the

Tone Detection Verification Test,

for example, you may also clear errors g enerated from

other tests in the testing sequenc e.

Tone Detection Verification Test (#42)

This test verifies the "touch-tone digits detec tion" capability of the DTMR port is

functioning properly.

Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Tone Detection Verification Test (#42) X X ND
Tone Detector Audit/Update Test (#43) X X ND
Table 3-257. TEST #42 Tone Detection Verification Test
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test
or there was an internal system error.
1 ABORT The system could not allocate all the resources needed to test the DTMR
port.
1001 ABORT The system was unable to put the DTMR port in the appropriate mode to
test it.
1002 ABORT The system could not allocate time slots for the test connection. This could
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm [a|b] command. Refer to
the TDM-BUS (TDM Bus) Maintenance documentation for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page