DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-413CO-TRK (CO Trunk)
3
1924 ABORT No test tone from far end
1. See actions for error code 19 05.
1938 ABORT Near-end self test failed.
1. Test the TN798 circuit pack.
1939 ABORT Loss self check at 0dBm at 1004 Hz failed.
1. Test the TN798 circuit packs.
2. If the test continues to abort escalate the problem.
1940 ABORT Far end noise self check failed.
1. The problem is with the far end system; a technician at the far end
should test the test line.
1941 ABORT High frequency singing return loss self check failed.
1. Test the TN798 circuit packs.
1942 ABORT Echo return loss self check failed.
1. Test the TN798 circuit packs.
1943 ABORT Singing return loss self check failed.
1. Test the TN798 circuit packs.
1944 ABORT Loss self check at -16 dBm at 1004 Hz failed.
1. Test the TN798 circuit packs
1945 ABORT Loss self check at -16 dBm at 404 Hz failed.
1. Test the TN798 circuit packs.
1946 ABORT Loss self check at -16 dBm at 2804 Hz failed.
1. Test the TN798 circuit packs.
1947 ABORT Noise with tone self check failed.
1. Test the TN798 circuit packs.
2000 ABORT The test timed out while waiting for a response from the TN798 circuit
pack.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2012 ABORT An internal software error occurred.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2053 ABORT The test call could not be established, but no information on why is
available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-178. TEST #844-848 Transmission Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page