DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-479DID-TRK (DID Trunk)
3
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension, attendant number, or trunk group/member number of the port.
Use the status station, status attendant, or status trunk command to
determine the service state of the port. If the service state indicates that
the port is in use, then the port is unavailable for certain tests. You must
wait until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test. This
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL This test can fail due to on-board or off-board p roblems. Off-board
problems of concern include EXP-INTF faults, TDM-BUS faults, and faults
associated with the tone detectors/tone generators. Clear all off-board
problems before replacing the board. Keep in mind that a TDM-BUS
problem is usually the result of a faulty board connected to the backplane
or bent pins on the backplane.
1. Look for EXP-INTF errors in the error log. If present, refer to the
EXP-INTF Maintenance documentation.
2. Look for TDM-BUS errors in the error log. If present, refer to the
TDM-BUS Maintenance documentatio n.
3. Look for TONE-BD and/or TONE-PT errors in the error log. If present,
refer to the TONE-BD Maintenance documentation and the TONE-PT
Maintenance documentation.
4. Test the board when the faults from steps 1, 2, and 3 are cleared.
Replace the board only if the test fails.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated using other port tests and by examining
station, trunk, or external wiring.
Table 3-201. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page