DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-303status sys-link
2
Output
The following example shows the output from the status sy s-link 01a0516
command.
If a faulted path exists in ad dition to the current path , the components making u p
the faulted path disp lay on page 2 of the repor t:
Field descriptions
Location Port location (cabinet-carri er-slot-circuit)
Type/Chan Type of system-link: PRI (ISDN-PRI signaling link)
Alarms Highest alarm level currently log ged against the c omponents
making up the link.
Current Path Operational status of the current p ath:
none: link is down.
present: current path disp layed is valid.
Faulted Path The status of the faulted path, if any:
present: path of the link has b een faulted at least once.
none: no record of the link having gone down
default: default faulted p ath is being used
Last Fault Date and time at which the most rec ent fault occurred
State Whether the system link is up or down
status sys-link 01a0516 Page 1 of 2
Location: 01a0516 Type/Chan: PRI Alarms: none
Current Path: present Faulted Path: present Last Fault: 04/30/1997 14:18
State: up
Current Hardware Path
Maintenance Maintenance
Location Name Alarms Location Name Alarms
01A PKT-INT major
PN 01 TDM-BUS none
status sys-link 01a0516 Page 2 of 2
Location: 01a0516 Type/Chan: PRI Alarms: none
Current Path: present Faulted Path: present Last Fault: 04/30/1997 14:18
State: up
Faulted Hardware Path
Maintenance Maintenance
Location Name Alarms Location Name Alarms