DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-90AN-LN-PT (Analog Line Port)
3
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCS Spp command to determine the station
extension.
2. Use the status station
extension
command to determine the service
state of the port.
3. If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ig nored.
1018 ABORT Administration has disabled the test. The default for the Test? field on the
station form is y. Determine why this field has been set to n on this station
(this may be due to the ringing application Test 48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station
extension
.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
FAIL The reflective Looparound Test failed. This could cause noisy or unreliable
connections, or users calling this port may hear an echo. The problem can
also be off-board.
1. Since a line seizure may affect the test, repeat the test at 1-minute
intervals for no more than 5 times.
2. Using the test board UUCSS short command, run circuit pack tests
to check the tone generator and the tone detector circuit p acks.
3. Resolve any problems on the tone generator or the tone detector
circuit packs.
4. If the tone generator and tone detector circuit pac ks are functioning
properly, determine if a voice terminal is connected and wired
properly. Resolve any problems found.
5. If the test still fails, replace the analog line circuit pack.
PASS The port provides an analog transmission path to the station equipment.
Investigate user-reported troubles on this port by running other port tests,
by examining station wiring, or by inspecting the station.
Table 3-35. TEST #161 Looparound Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page