DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-921PMS-LINK (Property Management System Link)

3
Link Retry Test (#215)
This test sends a message to the PMS software process to make a d ata call to the extension where the PMS device connects. If the PMS Link is already up, th en this test passes without making any d ata call.
Table 3-395. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10
20 ABORT Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
30 ABORT Internal System Error.
1. Refer back to the ‘‘Procedures for Restoring the PMS Link’’ section for
resolution.
1010 ABORT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms command to execute the test.
FAIL The PMS Link CANNOT be established.
1. Refer back to the ‘‘Procedures for Restoring the PMS Link’’ section for
restoring the PMS Link.
PASS The PMS Link is up.
Continued on next page