DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-15ADX8D-PT (AUDIX Digital Port)
3
While the primary information channel is still loop ed around, the Control Channel
Loop Around Test is performed. The Loop Around Test for the secondary
information (data) channel is then p erformed. This test is the same as the primary
information channel loop around test.
Next, a Conference Test is implemented for the pr imary information channel. This
test is the same as Conference Test #6.
Only one value (Pass, Fail, or Abort) is generated as a result of the four tes ts run.
If any test fails or aborts, the sequenc e is stopped.
Table 3-7. TEST #13 Voice and Control Channel Local Loop Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be in
use. Use the display port PCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in use, you
must wait until the port is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1001 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or may have time slots that are out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors, and is not handling heavy traffic,
retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out-of-service .
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors.
3. If neither condition exists, retry the command at 1-minute intervals a
maximum of 5 times.
1004 ABORT The port was put in use during the test. Use the display port PCSSpp to
determine the voice p ort extension of the port. U s e the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, you must wait until the port is idle before
retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page