DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-214set tone-clock
2
Field descriptions
set tone-clock
This command sets the active tone/c lock for a PN that has a duplic ated
tone/clock circ uit pack. Technicians should reset the d efault active tone clock in
each PN after using the set tone-clock command. If it is not in use, a single
failure can cause an unnecessa ry service outage. The sched ule maintenance
tone-clock switch op tion does not reset the tone-cloc k to the default active if it
was not active at the beginni ng of the test.
set vector
This command specifie s restart levels for core dumps and places core d umps on
primary Mass Storage System (a tape in a tap e system and core dump memory
cards in a memory card system) devices for later examina tion. The set vector
command allows technic ians to tailor restart levels that cop y memory to primary
Mass Storage System devices.
NOTE:
Software never requests an extended reboot.
To force an immediate core dump, set the ap propriate bit using thi s command,
then enter the reset system command at a level that forces core dumps
corresponding to set vector bits.
When a system restart occurs in a simplex sys tem with the corresponding vec tor
bit set, the core dump writes to secondary storag e (the primary MSS device).
Once the core dump writes, the vector clears and the restart executes.
Day of the Week: Monday through Sunday
Day of the Month: 1-31; the system also checks for leap year.
Month: January through December
Year: 1970-2999
Hour: 0-23
Minute: 0-59
Second: The system sets this field to zero when the time of day c lock is set.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
set tone-clock
location
override
Tone/clock location: PC
Forces the set command into
effect regardless of the tone/clock
circuit pack’s health.
init
inads
craft
1 (one) none