DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1038TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system, alway s investigate tests in the order listed
below. By clearing error cod es associated with the

Control Channel Loop Around

Tes t ,
for example, you may also clear errors g enerated from other tests in the
testing sequence.
Clear Error Counters Test (#270)
This test is nondestructive. This test clears the various error c ounters associated
with each TBRI-PT. This test passes if Maintenance is able to succ essfully send
the downlink messages; otherwise, the test ab orts.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
BRI Local LAN Port Loop Around Test (#618) X D
BRI TDM Port Loop Around Test (#619) X D
L1 State Query Test (#1242) X X D
CRC Error Counter Test (#623) X ND
Receive FIFO Overflow Test (#625) X ND
Layer 3 Query Test (#1243) X ND
Slip Query Test (#1244) X X ND
Clear Error Counters Test (#270) X X ND
NPE Crosstalk Test (#617) X D
Table 3-458. TEST #270 Clear Error Counters
Error
Code
Test
Result Description/ Recommendation
Any ABORT Maintenance could not send the downlink message.
PASS The message to clear the error counters of the TBRI-PT maintenance
object has been sent.
Continued on next page