DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1041TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)
3
BRI Port Local TDM Looparound Test (#619)

This test is conditionally destructive.

This test verifies the connectivity of a BRI port ac ross the TDM Bus. It aborts if

calls associated with the p ort are in progress. Failure of this test indic ates an

on-board fault associated with the port hardware on the circ uit pack.

Table 3-460. TEST #618 BRI Port Local LAN Loop Around
Error
Code
Test
Result Description/ Recommendation
1015 ABORT The port is not out-of-service.
1. Use the status bri-port PCSSpp command to determine the status of
the port.
2. If it is in use, wait until it is idle, and then use the busyout port
PCSSpp command to place it in the out-of-service state and repeat
this test.
!CAUTION:

Since the busyout command is destructive, execution of this

command prior to the p ort being idle causes all calls

associated with the BRI port to b e torn down.

1141 ABORT The PKT-INT is out-of-service.
1. Follow the repair procedures for the PKT-INT.
2. Run the test port long PCSSpp command and verify the repair by
viewing the results of the BRI Port Local LAN Looparound Test (#618).
2012
2100 ABORT Internal System Error.
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The Looparound Test failed.
1. If the test fails repeatedly, attempt to reset the circuit pack with the
busyout board PCSS and the reset board PCSS commands if the
other ports on the board are not in use.
2. If the test fails again, execute test pkt P.
3. If the tests in Step 2 pass, the problem is local to the BRI board.
Replace the trunk circuit pack.
PASS The BRI Port Local LAN Looparound Test pass ed.
Continued on next page