DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-27ADX16A-PT (AUDIX Analog Line/Control Link)
3
ADX16A-PT (AUDIX Analog Line/Control Link)
!CAUTION:

Never do any of the following without first shutting down AUDIX. Follow

instructions in the ‘‘Po wer Do wn AUDI X System’ section in Chapter 1,

‘‘Maintenance for csi systems’’.
The ADX16A-PT maintenance object represents a port on a TN566/TN2169
DEFINITY AUDIX circuit pack that is operating in control-link (CL) mode. For
circ uit-p ack- level p robl ems (AD X16A-BD or ANL -16-BD ), see “ XXX-BD (C ommon
Port Circuit Pack)”. For port-level problems with AUDIX operating in digital-port
mode, see ADXDP-PT/ADX8D-PT.
The tests described in this section apply only to switc h-side maintenance whic h
tests circuit pack components related to the TDM bus interfac e. The AUDIX
system has an extensive maintenance strateg y that is described in

DEFINITY

AUDIX System Maintenance
, 585-300-110.
AUDIX resides on a combined p air of circuit pac ks: the TN566 Multifunction
Board (MFB) and the TN2169 Alarm Board (ALB). Bec ause of its size this
combination occ upies 5 slots, but only 1 slot is func tional as far as the switch is
concerned. The other 4 slots are seen b y the switch as ‘‘AUDIX-reserved’’ slots.
In CL mode the TN566 pack sup ports up to 16 voice p orts. When a call to a
station with an AUDIX login is not answered, AUDIX answers the cal l using one of
the available voice por ts.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command To
Run1
1. Where P is the port network number (1 for PPN); C is the carrier designation (for example, A, B,
or C); SS is the address of the slot in the carrier where the circuit pack is located (for example, 01,
02, ..., etc.); and pp is the 2-digit por t number (for example, 01).
Full Name of MO
ADXCL-PT o r
ADX16A-PT MINOR test port PCSSpp l AUDIX Analog Line/ Control Link
ADXCL-PT o r
ADX16A-PT WARNING test port PCSSpp sh AUDIX Analog Line/ Control Link