DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-88AN-LN-PT (Analog Line Port)
3
PASS The station is connected properly to the switch. Investigate user-reported
troubles on this port by running other port tests, by examining station
wiring, or by insp ecting the station.
NOTE:
This test may also pass if no terminal equipment is connected and
the terminal is located very far from the switch.
0NO
BOARD The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the
list configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS
command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This re-establis hes the
link between the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is
inserted.
Table 3-34. TEST #48 Station Present Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page