Maintenance Objects
3-670H323-BCH (H.323 B-Channel)
3
Notes:
a. Error Type 18: this error indicates that this spec ific H323 trunk group
member has been
craft
busied-out.
System Technician Commands
The following commands are available to the system technician:
busyout port UUCSSpp – this command on a spec ific H.323 B-channel
drops any active c all that may exist on that B-channel and effec tively
reduces the trunk group capacity by one. N o physical piece of h ardware
is removed from service.
release port UUCSSpp – this command on a sp ecific H.323 B-channel
effectively increases the trunk group capacity b y one. No physical piec e
of hardware is actually add ed to service.
status trunk grp/mbr – this command is used to find the current status of
the specific B-c hannel. Additional status for a n H.323 B-channel shows
near and far-end IP signaling ad dresses, near and far-end H. 245
addresses, tunneling status, c all reference value for an active c all and the
H.323 conference ID.
test port UUCSSpp – this command results in the message No tests
applicable to this object.