DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-841MMI-BD
3
Control Channel Looparound Test (#52)
Refer t o the r epai r proc ed ure d escr ibed in th e XXX-BD ( Commo n Port Circu it
Pack) maintenance docum entation as Control Channel Looparound Test (#52).
SAKI Sanity Test (#53)
Refer t o the r epai r proc ed ure d escr ibed in th e XXX-BD ( Commo n Port Circu it
Pack) maintenance docum entation as SAKI Sanity Test (#53).
FAIL The MMI circuit pack is out of MMI synchronization. Run the long option of the
test board command.
1. Wait up to 5 minutes, and then reset the circuit pack with these
commands: busyout board PCSS, then reset board PCSS, followed by
release board PCSS.
2. Rerun the test; if the same result occurs again, replace the circuit pack.
1100 PASS The MMI circuit pack is providing the synchronization correctly. This MMI
circuit pack is designated as the Master Sync source.
1101 PASS The MMI circuit pack is listening to the synchronization signal correctly.
Table 3-365. TEST #1122/1123 MMI Synchronization Status TestContinued
Error
Code
Test
Result Description/Recommendation
Continued on next page