DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1020SYS-PRNT (System Printer)
3
Table 3-452. TEST #215 Link Retry Test
Error
Code
Test
Result Description/ Recommendation
10, 20 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 2 times.
30 ABORT Internal system error
1. Refer to the ‘‘Procedures for Restoring the System Printer Link’’ section
for recommended maintenance strategy.
1010 ABORT The System Printer Link has been busied out.
1. Enter the release sp-link command to release the System Printer Link
from the busyout state.
2. Reissue the test sp-link long command to execute the test.
FAIL The System Printer Link CANNOT be established.
1. Refer to the ‘‘Procedures for Restoring the System Printer Link’’ section
for recommended maintenance strategy.
PASS The System Printer Link is up.
Continued on next page