DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-870PE-BCHL (PRI Endpoint Port)

3
column indicates p ossible reasons why the port is in this state, and the right column suggests p ossible recovery mechanisms . If an alarm against PE-BCHL is present, it is indicated below the "X."
NOTE:
Refer to ‘‘Troubleshooting PRI Endpoint Problems’’ in Chapter 1, ‘‘Maintenance for csi systems’’ for a layered approach to the proc essing of PRI Endpoint problems.
Table 3-375. PRI Endpoint Port Service States
Possible
Problem
Source
O/S-NE
O/S-FE
O/S- FE Pend- ins
maint-NE
maint- FE
maint-FE Pend- ins
INS
Possible Recovery
Route
ISDN
wideband
calls being
completed.
X Normal Operation.
Port bu sied
out by
system
technician?
X Warn
Alarm Release port by the
release pri-endpoint
extension or release
port PCSSpp.
NPE
Crosstalk
Test failed?
X
Minor
Alarm
Replace UDS1
Interface CP.
DS1 circuit
pack lost
signal?
X UDS1 Interface CP
removed?
DS1 cable
disconnected?
Terminal adapter
problems?
Far-end terminal
adapter restarting?
Faulty UDS1 Interface
CP?
Check
UDS1-BD. Refer to UDS1-BD for
repair procedures.
Continued on next page