DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-696HYB-LINE (Hybrid Line)
3
1004 ABORT The port was seized by a valid call during the test. The test has been
aborted. Use the display port PCSSpp command to determine the station
extension number of the port. Use the status station command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in use
(off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1,2,3 FAIL The control channel between the processor and the p ort is not transmitting
properly. This port is not operable.
1. Retry the test.
2. If the failure still occurs, issue the busyout and the release busy
commands, and then retest.
3. If the failure is occurring on more than one port on the board, suspect
the board.
4. If the failure is occurring on several boards in the same carrier,
escalate the problem.
5. If the failure still occurs and appears to be isolated to one port, chec k
all wiring to the set and all set connections.
6. Replace the circuit pack as a last resort.
PASS Hybrid Line Local Digital Loop Around Test passed. The control channel is
transmitting properly.
1. If complaints still exist, investigate by using other circuit pack tests,
and by examining the station, wiring, and connections.
Table 3-293. TEST #58 Hybrid Line Local Digital Loop Around TestContinued
Error
Code
Test
Result Description/ Recommendation
Continued on next page