2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. Reset the circuit pack (busyout board UUCSS, reset board UUCSS,
and release board UUCSS).
2. If the test fails again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1003 FAIL Ping to the destination failed due to on-board problem.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
3. If the problem persists, re-administer the ethernet connection through a
different ethernet port, if available.
4. If the problem still persists, or if there are no other available ethernet
ports, replace the circuit pack.
1007 FAIL Ping to the destination failed due to the destination down.
1. Verify that at least one destination reachable through this port is up.
Ping this destination (ping ip-address xxx.xxx.xxx.xxx).
2. If the ping to any destination is successful through this port, the link is
up, although some destinations are unreachable. Ignore the failure.
3. If ping to all destinations fail, test this port (test port UUCSSpp short)
and follow repair procedures for Session Status Test (#1286) failures.
PASS TCP/IP Ping Test (#1281) is successful.
Table 3-269. TEST #1281 TCP/IP PING Test — Continued
Error
Code
Test
Result Description/ Recommendation