DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-527DIOD-DS1 (DS1 DIOD Trunk)
3
n. Error Type 3840Port Audit and Update Test (#36) failed due to an
internal system error. Enter the status trunk command to verify the status
of the trunk. If the trunk is out-of-service, then enter the r elease trunk
command to put it b ack into in-service. Retry the test c ommand.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order they are p resented in the table b elow when
inspecting errors in the system. By clearing error c odes associated wi th the
NPE
Crosstalk Test,
for example, you may also clear errors gene rated from other tests
in the testing sequenc e.
NPE Crosstalk Test (#6)
One or more Network Processing Elements (NPEs) resides on each circ uit pack
with a TDM Bus interface. (The TN464 UDS1 circuit pack has one SCOTCH-NPE
chip instead of several NPE chips.) The NPE controls port connectivity and g ain,
and provides confe rencing functions on a p er-port basis. The NPE Crosstalk Test
verifies that this port’s NPE channel talks on the selec ted time slot and never
crosses over to time slots reserved for other c onnections. If the NPE is not
working correctly, one-way and noisy connections may be ob served. This test is
usually only part of a port’s Lon g Test Sequence and takes about 20 to 30
seconds to comp lete.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
DS1 Dial Tone Test (#314) X X ND
Port Audit and Update Test (#36) X X ND