DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-446DATA-CHL (Data Channel)
3
1000 ABORT For this test, an Error Code of 1000 can have one of several different
meanings:
a. The target DATA-CHL is busy and, therefore, not availab le for use.
b. System resources required to run this test are not available.
c. Internal system error
Determine if the target DATA-CHL is in use for some other function (that is,
CDR Link, System Printer Link, Jou rnal P r inter Link, PMS Link, or secondary
administration terminal connection) as described previously in the ‘‘Status
of Data Channels’’ section. If so, check for errors on the function that is
using the DATA-CHL. If there are no errors, there is a high probability that
the DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to completely
test the target DATA-CHL:
1. If the target DATA-CHL is in use for some other function, busyout the
funct ion (PRI-CDR/ SEC-CDR, SYS-PRNT, PMS-PRN T/JNL-PRNT,
PMS-LINK) or the DATA-CHL (secondary administration terminal
connection only).
2. Retry the command at 1-minute intervals a maximum of 5 times.
3. Restore a ny busied out PRI-CDR/SEC -CDR, SYS-PRNT,
PMS-PRNT/JNL-PRNT, PMS-LINK MOs to service before moving on to
another activity.
1006 ABORT For this test, an Error Code of 1006 can have one of several different
meanings:
a. System resources required to run this test are not available.
b. Internal system error. Retry the command at 1-minute intervals a
maximum of 5 times.
1016 ABORT Resources for the test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1018 ABORT Test disabled via software patch.
2000 ABORT Internal system error
2003 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-189. TEST #111 Data Channel Local Loop Back Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page