Maintenance Objects
3-807MEDPROPT (TN802 MED PRO DSP PORT)
3
Notes:
a. Error Type 1 - this error type indicates that less than th ree DSPs are out of
service (OOS), and no alarm is raised . The Aux Data field contains the
number of DSPs that are Out of Service (OOS).
b. Error Type 258 - this error type indicates that more than three, b ut less
than 9 DSPs are out of service (OOS), and a WARNING alarm is raised.
The Aux Data field contains the number of DSPs that are Out Of Service
(OOS).
c. Error Type 515 - this error type indicates that all DSPs are out of service
(OOS), and a MINOR alarm is raised. The Aux Data field c ontains the
number of DSPs that are Out Of Service (OOS).
d. Error Type 18 - the MEDPRO has been busied out by a busyout port
UUCSS command.
1. Release the port (release port UUCSS).
515(c) DSP Capacity
Query Test
(##1382)
MINOR ON test board UUCCSS l r5
18(d) 0 busyout port
UUCSS WARNING OFF release port UUCCSS
769 Any TDM NIC
Looparound Test
(#1380)
MIN ON test port UUCCSS l r10
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
Table 3-349. ME DPROPT Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page