DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands

2-385test trunk

2
test trunk

This command performs hardware diagnostic tests on an entire trunk group or an

individual trunk group member, depend ing on the options entered.

Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test trunk
group
number
member
number
short
long
repeat
number
clear
schedule
Administered group number (1-99)
Administered number identifying a
particular trunk within a trunk group (1-99).
Command executes a series of
nondestructive diagnostic tests.
Command executes a more
comprehensive and longer version of the
both destructive and nondestruc tive
diagnostic tests.
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The command
is then placed in the command queue and
is executed at the specified time. The
information displayed by the command is
sent to the system printer instead of the
screen.2
Examples:
test trunk 78 l
test trunk 80/1 sh r 2
test trunk 78/2 l r 25
test trunk 78/2 l r 25 schedule
test trunk 80
test trunk 80 schedule
test trunk 78 r 4
test trunk 78 c
1 If no alarms are registered against the maintenance object then the test seq uence will be exercised only once. The
long clear
option forces a clear of all alarms if no errors are encountered during testing. The
short clear
option only
clears alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
cust
Test Seq. =
short;
Repeat = 1
none