DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands

2-383test tone-clock

2
test tone-clock

The test tone/clock command p erforms hardware diagnostic tests on a specified

tone or clock circ uit pack.

Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
tone-clock
location
short
long
repeat
number
clear
schedule
PCSS
Option for a brief series of
nondestructive diagnostic tests .
Option for a longer, more
comprehensive series of both
destructive and nondestruc tive
diagnostic tests.
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and then a
scheduling form disp lays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test tone-clock 01a l
test tone-clock 01b l schedule
1 If no alarms are registered ag ainst the maintenance object then the test sequenc e is run only once. The
long clear
option forces a clear of all alarms if no errors are enc ountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
Sequence
= short;
Repeat =
1
none