DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-370CLSFY-PT (Call Classifier Port)

3
Tone Detector Audit/Update Test (#43)
A sanity audit is performed on the CLSFY-PT (Call Classifier Port).
1-3 FAIL DTMF digits were not detected correctly. This may or may not impact
reception of R2-MFC calls.
1. Run the short test sequence via the test port PCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but
system capacity will be reduced. In order to restore system
performance to normal, replace the Call Classifier circuit pack
containing the defective CLSFY-PT (Call Classifier Port).
101-122 FAIL Forward or Backward MFC signals were not correctly generated or
detected. This impacts reception of incoming MFC calls.
1. Run the short test sequence via the test port PCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but
system capacity will be reduced. In order to restore system
performance to normal, replace the Call Classifier circuit pack
containing the defective CLSFY-PT (Call Classifier Port).
PASS Tone Detection Verification is successful. The Call Classifier Port
(CLSFY-PT) is able to detect/generate all necessary tones.
Table 3-165. Tone Detector Audit/Update Test (#43)
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test.
1. Wait 1 minute, and repeat the command a maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 3-164. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page