DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-333test ds1-loop
2
Output
The following example shows the output from the test data-module 300
command. The responses d isplay on a test-by-test b asis with one line of data for
each test result.

Field Definitions

test ds1-loop
This command validates that the b oard exists at the spec ified location and that
the board is a TN464F or TN767E or later suffix DS1 Interface board.
Long-duration loopb ack tests execute for an extend ed period of t ime until
manually terminated. Short-duration loopb ack tests return the result of the test to
the screen after executing. The list measurements ds1 summary command
can be used to monitor the s tatus of a long-duration loop back/span test.
Port Port address (cabinet- carrier-slot-circuit)
Maintenance
Name The name of maintenance object
Alt. Name Alternate way to identify maintenance ob jects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group numb er
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line group
number)
Test No The test being executed
Result Test result: Pass, Fail, Abort, No Board
Error Code Numeric code exp laining why the release failed or ab orted. Refer
to the detailed list of the cod es by test number for eac h MO.
test data-module 300
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C1103 PDMODULE 17 PASS
Command successfully completed