DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-240ATM-TRK (Circuit Emulation Service Circuit Pack)

3
1. Check for PKT-BUS al arms.r. Error Type 3585: Major board alarm; failure of critical c omponents involved in the operation of the circuit pack. The circuit pac k has failed, and the switch may no longer reco gnize it.1. Run test board UUCSS long.
If Then
There is a
packet-bus
alarm.
There is probably a packet-bus problem,
particularly if other circuit packs on the packet bus
report the same error. See the PKT-BUS (Packet
Bus) maintenance object and the packet-bus
fault-isolation and recovery sections of the
maintenance manual for repair procedures.
There are no
packet-bus
alarms.
Run the following command sequence:
busyout board UUCSS
reset board UUCSS.
test board UUCSS long
release board UUCSS
The problem
persists. Replace the ATM-TRK circuit pack.
Aux
Data Description
1 ATM framer chip failure
2 NCE failed
4 TDM PLD failed
5 All DSPs on the circuit pack have failed
6 Receive Network Processor (RNP) failed
7 Transmit Network Processor (TNP) failed
8 MEMORY read/write failure
9 DUART failure
If Then
Test #1259 fails with Error
Code XXYY a nd XX is an
AUX value in the
preceding table
Replace the ATM-TRK circuit pack.
The system does not
recognize the circ uit pack Replace the ATM-TRK circuit pack.