DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-496DIG-IP-STN (Digital IP Station)

3
Digital Terminal Lamp Update (#16)

This test updates internal lamp states that may or may not be disp layed on the

actual PC graphical user interface. The lamp upd ates will run only if the station is

in-service. The status of the station is chec ked and the lamp up dates are

blocked from taking place if the station is not in the in-ser vice state. This test

does not affect the status of the Messag e Waiting lamp.

Table 3-208. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error type is present, then release the port via the release station
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension of the port.
Use status station to determine the service state of the port. If the port is
in use, wait until the port is idle before testing.
2. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
PASS The message to light all of the station lamps was sent successfully to the port.
Continued on next page