DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-637E-DIG-STA (Emulated Digital Line)

3
Station Lamp Updates Test (#16)

This test lights all lamps on the terminal as sp ecified. The lamp upd ates will run

only if the station is in-service. The status of the station is c hecked and the lamp

updates are bloc ked from taking plac e if the station is not in the in-service state.

This test does not affect the status of the Message Waiting lam p.

7 FAIL Conference Test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may
not work at all.
14 FAIL The primary voice channel is not transmitting properly. User impact may
range from noticing nothing to not being able to use this port.
15 FAIL The control channel between the processor and digital circ uit pack is not
transmitting properly. User impact may range from noticing nothing to not
being able to use the port. This could disrupt other users.
16 FAIL The secondary voice channel is not transmitting properly. User impact
may range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit pack and
the Tone Detector circuit pack using the test board PCSSpp
command.
2. Resolve any problems that are detected on the Tone Generator circuit
pack or Tone Detector circuit pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly and the test still fails, replace the Digital Line circuit pack.
PASS The test passed, and all channels are transmitting properly.
1. To ensure that this is not an intermittent problem, repeat this test up to
10 times.
2. If noisy connections for voice or corrupted d ata for data transfer
persist, examine the station, connections, and wiring.
Table 3-261. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page