DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-547DLY-MTCE (MO-DAILY)

3
system-parameters maintenance was being executed when the time-out period of 2 hours expired .Screen 3-3. Maintenance-Related System Parameters (change system-parameters maintenance) for R8r.Screen 3-4. New “Command Time-out” Entry in the LIST HISTORY Form.
change system-parameters maintenance Page 1 of 4
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Telephone Number: 5551212 Abbrev Alarm Report? y
Second OSS Telephone Number: 5551213 Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y Suspension Threshold: 5
Restart Notification? y
Test Remote Access Port? n
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Start Time: 22: 00 Stop Time: 04: 00
Daily Maintenance: daily Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no
list history
HISTORY
Date of Loaded Translation: no translation loaded
Date Time Port Login Actn Object Qualifier
9/18 16:13 MGR1 init logn
9/18 16:13 MGR1 init logf TIME-OUT
9/18 14:13 MGR1 init cha system-param maintenance