DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-1048TBRI-PT (TN2185 ISDN Trunk-Side BRI Port)

3
Layer 3 Query Test (#1243)

This test is nondestructive. This test is used to c heck the applic ation layer

communications across the in-s ervice ISDN D-Channel. The test passes if a

status enquiry message was suc cessfully sent, fails if the sig naling link is down,

and aborts if a quer y is already running or there is an intern al error.

4 FAIL Received a status of Level 1 Pendi ng Activation, the NT1 has a loss of
power indicating a problem with the NT1.
1. Follow the manufacturer-recommended repair procedures for the NT1.
2. Execute the test port PCSSpp command and review the results of the
Level 1 Status Inquiry test to verify the repair.
PASS This test indicates that Level 1 is activated or that software has taken the
port out of service.
Table 3-465. TEST #1243 Layer 3 Query
Error
Code
Test
Result Description/ Recommendation
1019 ABORT Test is already running.
1113 ABORT The signaling link is down.
1. Use the test port PCSSpp long command to clear any errors whic h
prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the
command. If this test aborts or fails, follow the repair procedure for the
Signaling Link Status Test.
1141 ABORT The PKT-INT is out-of-service.
1. Consult the repair procedure for PKT-INT.
Continued on next page
Table 3-464. TEST #1242 Level 1 Status Inquiry — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page