DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-785MAPD-BD (MAPD Interface Circuit Pack TN802)
3
Shutting down NT on the TN802

Before removing the TN802 circuit pac k from the carrier, shut Windows NTTM

down first by

following either proced ure

described in Table 3-327:

System Technician-Demanded Tests: Descriptions
and Error Codes

Investigate tests in the order they are presented in Table 3-328. By clearing error

codes associated with the NPE Connection Audit Test, for example, you may also

clear errors generated from other tests in the testing sequence.

Table 3-327. Windows NT shutdown procedures
Step Faceplate button PC interface
1. Push the recessed button on the front
faceplate and hold it in. Click on the “Start” button in the lower, lefthand
corner.
2. “M shut” flashes on the LCD display Click on “Shut Down.”
3. When shutdown is complete, “MSHUT
#” displays (“#” is blinking ). Choose the “Shut down the computer?” radio
button.
4. Remove the circuit pack. Click on “OK.”
5. Wait for the message indicati ng that shutdown
is complete.
6. Remove the circuit pack.
Continued on next page
Table 3-328. System Technician-Demanded Tests
Order of Investigation
Apply to
TN802?1
Short
Test
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND2
NPE Connection Audit Test (#50) Y X ND
Control Channel Loop Test (#52) Y X ND
Loss of Signal Alarm Inquiry Test
(#138) NXX ND
Blue Alarm Inquiry Test (#139) N X X ND
Red Alarm Inquiry Test (#140) N X X ND
Yellow Alarm Inquiry Test (#141) N X X ND
Continued on next page