DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-978RING-GEN (Analog Ring Generator)

3
Analog Ring Generator Query Test (#118)

This test requests the Active Tone-Clock circuit pac k to check the ringing

voltage. The tone/clock c ircuit pack replies with PASS if the ringing voltage is

adequate to ring the analog phones. If not, the active tone/c lock circuit pac k

replies with a FAIL. The Analog Ring Generator Query Test then reports the result.

1005 ABORT The tone/clock is unable to read the analog ringing voltage level when the
tone/clock is in the Processor Interface slot. This test is not available for the
Processor Port Network in this configuration.
PASS The active Tone/Clock has successfully been enabled to monitor the ringing
voltage level.
Table 3-431. TEST #118 Analog Ring Generator Query Test
Error
Code
Test
Result Description/ Recommendation
1
1000
1001
1003
1115
2012
2100
ABORT Could not seize the resources to run the test. Other maintenance is running
on the active tone/clock circuit pack.
1. Wait for the green LED on the active tone/clock circuit pack to go out;
(use the status port-network command to determine the Active
tone/clock circuit pack).
2. Rerun the test. If the test aborts again, refer to TDM-CLK (TDM Bus
Clock) Maintenance documentation.
2000 ABORT Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve all other tone/clock
problems first.
2. Rerun the test.
1005 ABORT The tone/clock is unable to read the analog ring ing voltage level when the
tone/clock is in the Processor Interface slot. This test is not available for the
Processor Port Network in this configuration.
Continued on next page
Table 3-430. TEST #117 Analog Ring Generator Initialization Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page