DEFINITY ECS Release 8.2 Maintenance for R8.2csi

555-233-119 Issue 1
April 2000

Maintenance for csi systems

1-130ATM Tips

1
Figure 1-58. List sys-link screenEnsure that the fields have the values indicated below.2. Enter show switch circuittable on the A500 console. Figure 1-59 shows the screen output.Figure 1-59. A500: show switch circuit screen

Link Type/

Channel One PACL to each TN230X in either a PPN or an EPN, and

one EAL to each TN230X in an EPN.

State up

list sys-link
SYSTEM LINKS INFORMATION
Location Link Type/ State Current Faulted Last Fault
Channel Path Path Recorded
02A0101 EAL up present present 12/06/1997 16:20
01B0202 PACL up present present 12/06/1997 16:17
02A0102 PACL up present present 12/06/1997 16:20
A500:show switch circuit
_______________________________________________________
| Input | Output | Connection |
| port vpi vci| port vpi vci| type class parameters |
|______________|______________|_________________________|
A1.1 0 5 Self 0 1 pp UBR ppd on
A1.1 0 32 A1.2 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.1 0 35 A1.2 0 35 pmp CBR pcr=173
A1.2 0 5 Self 0 2 pp UBR ppd on
A1.2 0 32 A1.1 0 32 pp VBRnrt pcr=5729 /scr=5729 /mbs=17187
A1.2 0 34 A1.1 0 34 pmp CBR pcr=173
Self 0 1 A1.1 0 5 pp UBR ppd on
Self 0 2 A1.2 0 5 pp UBR ppd on
_________________________________________________________