DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-1157TSC-ADM (Administered Temporary Signaling Connections)

3
1149 ABORT The ADMTSC is disabled.
1. Enable the TSC, and see if the status indicates "active."
2. Reissue the test tsc-administered com mand.
3. If the TSC still disabled, remove the ADMTSC from the system.
1181 ABORT Ran out of ADMTSC resources.
1. Reissue the test tsc-administered command at 1-minute intervals a
maximum of 3 times.
1182 ABORT The BX.25 link is down at the gateway.
1. Disable the ADMTSC.
2. Check the status of the gateway link via the status link link-no
command.
3. Once the gateway link indicates an "in-service" state, enable the
Administered TSC.
4. Reissue the test tsc-administered com mand.
2000 ABORT The Administered TSC is not responding to a TSC heartbeat inquiry.
1. Retry the test tsc-administered command at 1-minute intervals a
maximum of 3 times.
2. If the problem continues to fail, obtain the status of the D-channel or
D-channel pair associated with the ADMTSC via the status sig-group
<group> command. If the D-channel is INS (that is, in-service) and the
status of the ADMTSC appears to be active, disable and enable the
ADMTSC through administration. NOTE: To disable the ADMTSC,
display the (administration) Signaling Group Form via the change
sig-group <group> command where <group> refers to the number of
the signaling group under which the suspect TSC is administered.
Change the Enable field to n. To enable the ADMTSC, change the
Enable field to y.
3. Reissue the test tsc-administered com mand.
4. If the test fails, check the ADMTSC node on the other side of the
network to verify that the ADM TSC is indeed active.
2012 ABORT Internal System Error.
1. Reissue the test tsc-administered command at 1-minute intervals a
maximum of 5 times.
Table 3-508. TEST #604 TSC Heartbeat Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page