DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands

2-116list marked-ports

2
Output
Field descriptions
list marked-ports

This command lists all the ports th at have been marked unusab le with the mark

port command (maximum of fifteen marked ports per page).

Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
list
isdn-testcall
print
schedule
Report sent to printer.
Command is validated and then a
scheduling form displays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.1
Examples:
list isdn-testcall
list isdn-testcall print
list isdn-testcall schedule
1 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
none none
B-Channel Trunk in use for the ISDN-PRI test call (trunk group number/ memb er

number).

Start Time Time the test call started (dd /hh:mm format).
Duration Expected duration of the tes t call.
M/T Port The TN771 Maintenance/Test circuit pack’s d igital port ad dress (in

cabinet/carrier/slot/c ircuit format) in use for the outgoing asynchronous

ISDN-PRI test call.

list isdn-testcall
ISDN-PRI TESTCALLS
B-Channel Start Time Duration M/T Port
078/001 25/12:36 120 1B1102
Command successfully completed