DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance for csi systems
1-29Logging On/Off
1
To remove the Facility Test Calls Access Code, d o the following:
1. Enter change feature-access-codes to display the Feature Access Cod e
screen.
2. Leave the Facility Test Calls Access Code field blank.
!CAUTION:

No alarms report through the INADS interface if Alarm Origination is

disabled.

!CAUTION:

A busied out resource is one that is out of service. Be sure to verify if a

busied resource need s to be released or if the resource should remain

busied out.

Figure 1-6. Logoff Screen
To Display a Login
1. Enter the command display logi n [login name] and press Enter.
The system displays the requested login’s:
Name
Login type
Servic e leve l
Disable following a sec urity violation value
Access to INADS Port value
Password aging cycl e length
Facility test call notification and acknowledgment
Remote access notification and acknowledgment
Facility Test Call Administered
Remote Access Administered
Alarm Origination is currently disabled.
Active major or minor alarm detected; be sure to resolve it.
*** Busied out resource detected; verify if release is needed! ****
Proceed With Logoff: [n]