DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-212V-PWR (12 Volt Power Supply)

3
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes

Always investigate tests in the order p resented in the following table. By clearing

error codes associated with the

12 Volt Po wer Sup ply Test

for example, you may

also clear errors generated f rom other tests in the testing sequenc e. The 12 Volt

Power Supply Test can be initiated through either the test card-mem command

or the test network-control command.

Table 3-1. 12 Volt Power Supply Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board
Test to C le ar
Valu e
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test card-mem
12
2. Software cannot turn on the 12 volt power supply to provide 12 volt power to the flash memory or to
the translation card.
Any 12 Volt Po wer Sup ply Te st
(#701) MINOR ON test card-mem
2573
3. Software can turn on the 12 volt power supply, and 12 volt power is available. However, the software
cannot turn the power supply off after operations are completed . The 12 volt power remains on. This
error does not affect the normal operations involved in accessing the memory or the translation
card.
Any 12 Volt Po wer Sup ply Te st
(#701) WARNING ON test ca rd-mem
Table 3-2. System Technician-Demanded Tests: 12-V PWR
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence D/ND1
12 Volt Po wer Sup ply Te st (#70 1) X X ND
Memory Card Insertion Test (#695)2XX ND
Memory Card Format and Read Test (#696)2XX ND
Memory Card Match Test (#697)2XX ND
Memory Card Write-Protected Test (#698)2XX ND
Continued on next page