DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-53ANL-LINE (8-Port Analog Line), ANL-NE-L (8-Port Neon Analog Line)

3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. These are in-line err ors and can only be resolved over time.
40960indicates that too many simultane ous incoming ringing
attempts were made on this board . Only four ports on a board may be ringing simultaneousl y. A fifth incoming call will cause an inline error from the board.
Table 3-22. 8-Port Analog Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40960
40975
40977
None
15 (b) Any Audits and Updates
Test (#36)
18 0 busyout station
<extension> WRN OFF release station <extension>
130 (c) None WRN ON test port PCSSpp sh
257 (d) Station Present Test
(#48) WRN OFF test port PCSSpp sh r 3
513 Battery Feed Test
(#35) MIN/
WRN2
2. Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
ON test port PCSSpp sh r 2
769 (e) Loop Around and
Conference Test(#47) test port PCSSpp l r 3
1025 NPE Crosstalk Test
(#6) MIN/
WRN2ON test port PCSSpp l r 3
1281 (f)
1793 (f)