DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-307BRI-SET, ASAI-ADJ, BRI-DAT

3
1187 ABORT The circuit pack, port or station may have been busied out by a technici an.
1. Look in the Error Log for Error Type 18 (busied out ) for BRI-BD,
BRI-PORT, or BRI-SET.
2. If this error type is present for BRI-SET only, then r eleas e the statio n via
the release station command.
a. If this error type is present for BRI-PORT and BRI-SET, then re lease
the port via release port PCSSpp command and run the test
again.
b. If the error is present for BRI-BD, BRI-PORT, and BRI-SET, then
release the circuit pack via the release port PCSSpp command
and run the test again. If the error is present for both BRI-BD and
BRI-PORT, then release the circuit pack via the release board
PPCSS command and run the test again. If the error is present for
BRI-SET only, then release the circuit pack via the release port
PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you release all ports
associated with it. If certain ports still need to be busied
out, use the release port PCSSpp command to busy
them out.
3. Make sure the terminal is connected.
4. Retry the command at 1-minute intervals a maximum of 5 times.
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2068 ABORT The endpoint has rejected the switch sent application message. This
indicates that the endpoint does not support the ISDN-BRI Management
and Maintenance Procedure for Loop Back Testing.
1. Use the change station extension command and change the MIMs
Supported field to n.
2069 ABORT The endpoint has returned an error response to the application message
sent by the switch.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 3-134. TEST #627 BRI Remote Loop Back — Continued
Error
Code
Test
Result Description/ Recommendation