DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-314test access-endpoint
2
test access-endpoint

This command performs hard ware diagnostic tests on all p ort circuits that are

associated with the spec ified access end point extension.

Elapsed Time

since Task

Started:

Elapsed time since the TTI background task was started. If the task

is “not active”, then this fiel d is blank. If the task is “c ompleted” it

will indicate the length of time (hh:

mm

format) it took to complete

the task. If the task is “suspend ed”, then it will disp lay the elapsed

time at the point the task was suspend ed.

Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
access-
endpoint
extension
short
long
repeat
number
clear
schedule
Access endpoint extension (# of dig its
determined by dial-plan)
Option for a brief series of nondestructive
diagnostic tests.
Option for a longer, more comprehensive
test series (includes a destructive test)
How many times each test in the sequence
is repeated (1-100)
This option causes the test sequence (short
or long) to repeat until the alarm (if any) is
cleared or a single test in the sequence
fails.1
Command is validated and then a
scheduling form displays to schedule
execution of the command. The command is
then placed in the command queue and is
executed at the specified time. The
information displayed by the command is
sent to the system printer instead of the
screen.2
Examples:
test access-endpoint 25012
test access-endpoint 45002 sh
test access-endpoint 45892 l
test access-endpoint 24389 sh r 4
test access-endpoint 34899 l r 6
test access-endpoint 34912 l r 5 schedule
test access-endpoint 93483 r 2
test access-endpoint 10022 c
test access-endpoint 92349 schedule
1 If no alarms are registered against the maintenanc e object then the test sequence is run only once. The
long clear
option forces a clear of all alarms if no errors are enc ountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
nms
Test
sequence
= short;
repeat =
1
none