DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-301BRI-SET, ASAI-ADJ, BRI-DAT

3
System Technician-Demanded Tests: Descriptions
and Error Codes

When inspecting errors in the system and deciding which ones to address,

always investigate errors associated wi th the circuit pack and port first. Clearing

these error codes first may also c lear errors generated against the end point.

When all circuit pack and port errors have been clea red, and errors still exist

against the endpoint, alway s investigate errors in the order they are presented in

the table below. By clearing error codes associated with the

Signaling Link Status
Tes t ,

for example, you may also clear errors g enerated from other tests in the

testing sequence.

65 Bearer Service
Not Implemented Requested service not implemented in switch or
endpoint.
69 Requested
Facility Not
Implemented
Requested service not supported in switch or
endpoint.
1. Consult switch and endpoint doc umentation to
determine service support.
Adjunct switch
error conditions
81 Invalid CRV An invalid CRV was sent by the adjunct.
1. This may indicate a CRV inconsistency between
the switch and the adjunct. See the CallVisor
protocol reference manual.
Table 3-132. System Technician-Demanded Tests: BRI-SET
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
Signaling Link Status Test (#626) X X ND
BRI XID Test (#628) X X ND
BRI Layer 3 Query (#629) X (a) X (a) ND
BRI Remote Loop Back (#627) X (a) ND
BRI Set Audits (#630) X (a) X (a) ND
Continued on next page
Table 3-131. ISDN-BRI Cause Values — Continued
Code Explanation Recommendation
Continued on next page