Command
History This guide is platform-specific. For command information about other platforms,
refer to the relevant Dell Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced on the E-Series.
rmon hc-alarm
Set an alarm on any MIB object.
S6000
Syntax rmon hc-alarm number variable interval {delta | absolute}
rising-threshold value event-number falling-threshold value
event-number [owner string]
To disable the alarm, use the no rmon hc-alarm number command.
Parameters number Enter the alarm integer number from 1 to 65535. The value
must be unique in the RMON alarm table.
variable The MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object
type must be a 64-bit integer.
interval Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is from 5 to 3600 seconds.
delta Enter the keyword delta to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute Enter the keyword absolute to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
1334 Remote Monitoring (RMON)