Command Modes

Command History

Related Commands

For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then the slot/port information.

For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the slot/port information.

EXEC Privilege

This guide is platform-specific. For command information about other platforms,

refer to the relevant Dell Networking OS Command Line Reference Guide.

The following is a list of the Dell Networking OS version history for this command.

VersionDescription

9.7(0.0)

Introduced on the S6000-ON.

9.0.2.0Introduced on the S6000.

8.3.19.0Introduced on the S4820T.

8.3.11.1Introduced on the Z9000.

8.3.12.0Introduced on the S4810.

Legacy E-Series command.

fefd — enables far-end failure detection on an interface.

fefd reset — enables FEFD globally on the system.

fefd

Enable Far-End Failure Detection on an interface, set the FEFD interval, or select the FEFD mode.

S6000

Syntaxfefd {disableintervalmode {aggressivenormal}

Parameters

Enter the keyword disable to disable FEFD for the specified

disable

 

interface.

interval

Enter the keyword interval, followed by a value to specify the

 

FEFD interval in seconds. Range is from 3 to 300. Default is

 

15.

mode

Enter the keyword mode followed by the mode type to

 

specify the FEFD mode.

 

• normal: Change the link state to “unknown” when a far-

 

end failure is detected by the software on that interface.

 

When the interface is placed in an “unknown” state, the

 

software brings down the line protocol.

944

Layer 2

Page 944
Image 944
Dell 9.7(0.0) manual Fefd, Legacy E-Series command, Syntaxfefd disableintervalmode aggressivenormal