Syntax deny icmp {source address mask | any | host ipv6-address}
{destination address | any | host ipv6-address} [message-type]
[count [byte]] | [log [interval minutes] [threshold-in-msgs
[count]] [monitor]
To remove this filter, you have two choices:
Use the no seq sequence-number command syntax if you know the filter’s
sequence number
Use the no deny icmp {source address mask | any | host ipv6-
address} {destination address | any | host ipv6-address}
command
Parameters log (OPTIONAL) Enter the keyword log to enable the triggering
of ACL log messages.
threshold-in
msgs count
(OPTIONAL) Enter the threshold-in-msgs keyword
followed by a value to indicate the maximum number of ACL
logs that can be generated, exceeding which the generation
of ACL logs is terminated. with the seq, permit, or deny
commands. You can enter a threshold in the range of 1-100.
interval
minutes
(OPTIONAL) Enter the keyword interval followed by the
time period in minutes at which ACL logs must be generated.
You can enter an interval in the range of 1-10 minutes.
monitor (OPTIONAL) Enter the keyword monitor when the rule is
describing the traffic that you want to monitor and the ACL
in which you are creating the rule is applied to the monitored
interface.
Defaults By default, 10 ACL logs are generated if you do not specify the threshold explicitly.
The default frequency at which ACL logs are generated is 5 minutes. By default,
flow-based monitoring is not enabled.
Command
Modes
ACCESS-LIST
Command
History Version Description
9.7(0.0) Introduced on the S6000–ON.
9.4(0.0) Added support for flow-based monitoring on the S4810,
S4820T, S6000, and Z9000 platforms.
9.3.0.0 Added support for logging of ACLs on the S4810, S4820T,
and Z9000 platforms.
Usage
Information When the configured maximum threshold is exceeded, generation of logs is
stopped. When the interval at which ACL logs are configured to be recorded
expires, the subsequent, fresh interval timer is started and the packet count for that
314 Access Control Lists (ACL)