Line

Description

RX Power High

Factory-defined setting. Value can differ between SFP and

Warning threshold

SFP+.

Temp Low

Factory-defined setting. Value can differ between SFP and

Warning threshold

SFP+.

Voltage Low

Factory-defined setting. Value can differ between SFP and

Warning threshold

SFP+.

Bias Low Warning

Factory-defined setting. Value can differ between SFP and

threshold

SFP+.

TX Power Low

Factory-defined setting. Value can differ between SFP and

Warning threshold

SFP+.

Power Low

Factory-defined setting. Value can differ between SFP and

Warning threshold

SFP+.

Temperature

Current temperature of the SFPs. If this temperature crosses

 

Temp High alarm/warning thresholds, the temperature high

 

alarm/warning flag is set to true.

Voltage

Current voltage of the SFPs. If this voltage crosses voltage

 

high alarm/warning thresholds, the voltage high alarm/

 

warning flag is set to true.

Tx Bias Current

Present transmission (Tx) bias current of the SFP. If this

 

crosses bias high alarm/warning thresholds, the TX bias high

 

alarm/warning flag is set to true. If it falls below the low

 

alarm/warning thresholds, the TX bias low alarm/warning

 

flag is set to true.

Tx Power

Present Tx power of the SFP. If this crosses Tx power alarm/

 

warning thresholds, the Tx power high alarm/warning flag is

 

set to true. If it falls below the low alarm/warning

 

thresholds, the Tx power low alarm/ warning flag is set to

 

true.

Rx Power

Present receiving (Rx) power of the SFP. This value is either

 

average Rx power or OMA. This depends on the Rx Power

 

measurement type displayed above. If this crosses Rx power

 

alarm/warning thresholds, the Rx power high alarm/warning

 

flag is set to true. If it falls below the low alarm/warning

 

thresholds, the Rx power low alarm/warning flag is set to

 

true.

Data Ready state

This field indicates that the transceiver has achieved power

Bar

up and data is ready. This is set to true if data is ready to be

 

sent and set to false if data is being transmitted.

Rx LOS state

This is the digital state of the Rx_LOS output pin. This is set

 

to true if the operating status is down.

Tx Fault state

This is the digital state of the Tx Fault output pin.