Line Description
Rate Select state This is the digital state of the SFP rate_select input pin.
RS state This is the reserved digital state of the pin AS(1) per
SFF-8079 and RS(1) per SFF-8431.
Tx Disable state If the admin status of the port is down then this flag is set to
true.
Temperature High
Alarm Flag
This can be either true or false, depending on the Current
voltage value displayed above.
Voltage High
Alarm Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Tx Bias High
Alarm Flag
This can be either true or false, depending on the present Tx
bias current value displayed above.
Tx Power High
Alarm Flag
This can be either true or false, depending on the Current Tx
bias power value displayed above.
Rx Power High
Alarm Flag
This can be either true or false, depending on the Current Rx
power value displayed above.
Temperature Low
Alarm Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Voltage Low
Alarm Flag
This can be either true or false, depending on the Current
voltage value displayed above.
Tx Bias Low Alarm
Flag
This can be either true or false, depending on the Tx bias
current value displayed above.
Tx Power Low
Alarm Flag
This can be either true or false, depending on the Current Tx
power value displayed above.
Rx Power Low
Alarm Flag
This can be either true or false, depending on the Current Rx
power value displayed above.
Temperature High
Warning Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Voltage High
Warning Flag
This can be either true or false, depending on the Current
Voltage value displayed above.
Tx Bias High
Warning Flag
This can be either true or false, depending on the Tx bias
current value displayed above.
Tx Power High
Warning Flag
This can be either true or false, depending on the Current Tx
power value displayed above.
Rx Power High
Warning Flag
This can be either true or false, depending on the Current Tx
power value displayed above.
Temperature Low
Warning Flag
This can be either true or false, depending on the Current
Temperature value displayed above.
Voltage Low
Warning Flag
This can be either true or false, depending on the Current
Voltage value displayed above.
720 Interfaces