Parameters

Defaults

Command Modes

Command History

Usage Information

Related Commands

interval

Enter the keyword interval followed by the number of

seconds

seconds to wait between FEFD control packets. Range is

 

from 3 to 300 seconds. Default is 15 seconds.

normal

(OPTIONAL) Enter the keywords mode normal to change

 

the link state to “unknown” when a far-end failure the

 

software detects on that interface. When the interface is

 

placed in “unknown” state, the software brings down the line

 

protocol. The default is Normal mode.

aggressive

(OPTIONAL) Enter the keywords mode aggressive to

 

change the link state to “error-disabled” when a far-end

 

failure the software detects on that interface. When an

 

interface is placed in “error-disabled” state, t enter the fefd

 

reset command to reset the interface state.

Disabled.

 

CONFIGURATION

 

This guide is platform-specific. For command information about other platforms, refer to the relevant Dell Networking OS Command Line Reference Guide.

The following is a list of the Dell Networking OS version history for this command.

VersionDescription

9.7(0.0)

Introduced on the S6000-ON.

9.0.2.0Introduced on the S6000.

8.3.19.0Introduced on the S4820T.

8.3.11.1Introduced on the Z9000.

8.3.12.0Introduced on the S4810.

Legacy E-Series command.

If you enter only the fefd-globalsyntax, the mode is normal and the default interval is 15 seconds.

If you disable FEFD globally (no fefd-global), the system does not remove the FEFD interface configuration.

fefd — enables far-end failure detection.

fefd-global interval — configures an interval between FEFD control packets.

show fefd — shows the FEFD command output.